2.4.1液體二氧化碳的正常排放是在儲罐增壓后,開啟V2排液閥,V3回氣閥,液體二氧化碳便流入汽化器汽化,供使用點使用。
The normal discharge of liquid carbon dioxide is after pressurization of the tank, open the V2 drain valve, V3 return valve, the liquid carbon dioxide will flow into the vaporizer vaporization for use point.
2.4.2為滿足排液過程的穩(wěn)定壓力,應按“儲罐的增壓”操作方法進行增壓。
In order to meet the steady pressure of the drainage process, it should be pressurized according to the method of "pressurized tank".
【產(chǎn)品詳情圖片】
【標題】

1、操作前的準備 Preparation before operation
【產(chǎn)品詳情圖片】
1.1 操作者應按本說明書要求及有關文件進行操作。The operator shall follow the instructions and related documents to operate.
1.2正式投入使用前,用干燥的CO2氣體對整個系統(tǒng)進行吹除置換,吹除置換所用的氣體純度不低于充裝介質的純度。Formally put into use before the use of dry CO2 gas blowing the entire system replacement, purge replacement gas purity of not less than the purity of the filling
【產(chǎn)品詳情圖片】
【主變量】【變量3】【變量2】【變量1】

注意事項matters need attention
在您購買我公司的設備之際,請接收我們誠摯的謝意。我們嚴格按標準和工藝進行制造,但由于安裝和使用的不當,仍會引起意外事故。本使用說明書所示安全事項是為了您能安全正確的使用本設備,防止您或他人的危害或損害于未然,一旦實施錯誤的操作方法,其產(chǎn)生的后果均與安全有關。請接受本使用說明書的,并注意如下事項:
Please receive our sincere thanks for your purchase of our equipments. We manufacture in strict accordance with standards and craftsmanship, but will still cause accidents due to improper installation and use. The safety instructions in this manual are for the purpose of safe and correct use of this equipment, to prevent the harm to you or others from harm or damage, and once the wrong operation method is implemented, all the consequences arising therefrom are safety related. Please accept the instructions in this manual, and note the following:
1本設備屬于特種設備,要設專職人員管理與操作,操作人員要經(jīng)過培訓持證上崗,否則由于誤操作和使用,會造成危及生命安全的可能。
The equipment belongs to special equipment, which should be managed and operated by full-time personnel. Operators should be trained and certified to be on duty. Otherwise, it will be possible to endanger life safety due to misoperation and use.
2 本設備的安裝、使用及維修應符合JB6898-1997《低溫液體貯運設備 使用安全規(guī)則》的規(guī)定。本設備應放在室外、通風良好的場所。CO2有很強的窒息性,會引起窒息危險,甚至危及生命。
the installation, use and maintenance of the equipment shall conform to the provisions of JB6898-1997 "safe rules for the use of cryogenic liquid storage and transportation equipment". The equipment should be placed outdoors and well ventilated. CO2 has a strong asphyxiation, which can cause choking hazards and even life.
3 本設備貯存的是-40℃的低溫液體,管道、閥門凍結堵塞時嚴禁用重物敲擊、火烤或冷水噴淋等方法解凍,應用70~80℃干凈無油的熱空氣、熱氮氣解凍。
this equipment is to 40 ℃ cryogenic liquid storage, pipe, valves, frozen jams it is forbidden to use heavy percussion, fire, or cold water spray method of thawing, application of 70 ~ 80 ℃ clean hot air, hot nitrogen release without oil.
【產(chǎn)品詳情圖片】
【變量3】【變量2】【變量1】

充液的操作 filling operation
【標題】
充液分為充液和補充充液。
充液的操作如下:
Filling fluid is divided into the first filling and filling fluid.
The first filling operation is as follows:
2.1.1 儲罐吹除置換干凈達到要求后,將充液管線與儲罐的充液接頭連接,液位計組合閥處于平衡狀態(tài)準備充液。
After the tank blows off to replace the cleanliness meets the requirements, the filling liquid line is connected with the liquid filling joint of the tank, and the liquid level gauge combination valve is in an equilibrium state to be filled.
2.1.2充入與液體二氧化碳純度相同的氣體,使罐內壓力達到0.8 Mpa以上,方可進行充液。 filled with the same purity of liquid carbon dioxide gas, the tank pressure reached 0.8 Mpa above, before filling.
2.1.3 將充液管線接通槽車,先開啟V5殘液閥,排出管線內的雜質氣體后,再開啟V1進液閥和V7排氣閥,V8液位計組合閥處于全開狀態(tài),顯示液位計讀數(shù)進行充液。
The filling liquid line connected tanker, first open the V5 raffinate valve, exhaust gas impurities within the pipeline, and then open the V1 inlet valve and V7 exhaust valve, V8 level gauge combination valve is fully open state, Display level meter readings are filled.
2.1.4 在充液過程中,當液位計指示液位接近標定值時,可間斷開啟V4充滿指示閥,如有液體噴出,應立即停止充液,關閉V4充滿指示閥。
During the filling process, when the liquid level gauge indicates the liquid level approaches the calibration value, the V4 may be intermittently opened to indicate the valve. If any liquid is ejected, liquid filling should be stopped immediately and the V4 valve should be closed.
2.1.5關閉V1進液閥和V7排氣閥,打開V5殘液閥,拆下充液管線,充液結束。
補充充液的操作與充液的操作方法相似,不同點是補充充液時一開始就可以大量充液。
Close the V1 inlet valve and the V7 exhaust valve, open the V5 residual valve, remove the filling line, and fill with liquid.
The procedure for replenishing the priming solution is the same as for the first priming procedure, except that the priming solution can be replenished extensively from the beginning.